Belden Industrial Data Solutions ®- Industrial Data - DeviceBus ® for ODVA DeviceNetTM
CSE holds supplies a wide range of Belden cables - Contact our team for more information.
Belden 3084A
- 300V Class 2 Thin
- 22 and 24 AWG Stranded Tinned Copper
- 100% individually foil shielded + overall 65% TC Braid
- Drain Wire
- PVC Insulation (Power)
- FPE Insulation (data)
- Lt Gray sunlight / oil resistant PVC jacket
- Thin 75oC
- Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154 x 44) 17.5 Ω/ M', 57.4 Ω /km
- Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105 x 44) 28.0 Ω/ M', 91.9 Ω /km
- Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
- Nominal OD - 0.28", 7.11mm
Belden 3082A
- 300V Class 2 thick
- 15 and 18 AWG stranded tinned copper
- 100% individually foil shielded + overall 65% TC braid
- Drain Wire
- PVC Insulation (power)
- FPE insulation (data)
- Lt grey sunlight / oil resistant PVC jacket
- Thick 75oC
- Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (19 x 28) 3.6 Ω / M', 11.8 Ω / km, 18 AWG TC (19 x 30) 6.9 Ω / M', 22.6 Ω / km
- Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.9 Ω /km
- Nominal core OD - 0.460", 11.68mm
Belden 3082F
- 300V Class 2 thick
- 15 and 18 AWG stranded tinned copper
- 100% individually foil shielded + overall 65% TC braid
- Drain Wire
- PVC Insulation (power)
- FPE insulation (data)
- Lt grey sunlight / oil resistant PVC jacket
- Thick 75oC
- Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (65 x 33) 3.6 Ω / M', 11.8 Ω / km, 18 AWG TC (65 x 36) 6.9 Ω / M', 22.6 Ω / km
- Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.9 Ω /km
- Nominal OD - 0.460", 11.68mm
Belden 3082K
- Flat, 16 AWG stranded (19 x 29) tinned copper
- Unshielded
- PVC insulation (power)
- FPE insulation (data)
- Lt. grey sunlight-resistant PVC jacket
- Class 2 300V 75oC
- Conductor (stranding) Diameter Nom. DCR - 16 AWG TC (19 x 29) 4.9 Ω / M', 16.1 Ω / km
- Shielding materials Nom. DCR - unshielded
- Nominal OD - 0.760 x 0.210", 10.92 x 5.33mm
Belden 3082KP
- PVC insulation
- Black sunlight-resistant PVC jacket
- Conductor (stranding) Diameter Nom. DCR - 16 AWG TC (19 x 29) 4.9 Ω / M', 16.1 Ω / km
- Shielding materials Nom. DCR - unshielded
- Nominal OD - 0.760 x 0.210", 10.92 x 5.33mm
Belden 3083A
- PVC Insulation (power)
- FPE insulation (data)
- Yellow CPE jacket
- Thick 80oC
- Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (19 x 28) 3.6 Ω / M', 11.8 Ω / km; 18 AWG TC (19 x 30) 6.9 Ω / M', 11.8 Ω / km
- Shielding materials Nom. DCR - unshielded
- Nominal OD - 0.475", 12.07mm
Belden 3084F
- 300V Class 2 Thin
- 22 and 24 AWG Stranded Tinned Copper
- 100% individually foil shielded + overall 65% TC Braid
- Drain Wire
- PVC Insulation (Power)
- FPE Insulation (data)
- Lt Gray sunlight / oil resistant PVC jacket
- High flex Thin 75oC
- Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154 x 44) 17.5 Ω/ M', 57.4 Ω /km
- Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105 x 44) 28.0 Ω/ M', 91.9 Ω /km
- Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
- Nominal OD - 0.275", 6.99mm
Belden 3085A
- 300V Class 2 Thin
- 22 and 24 AWG Stranded Tinned Copper
- 100% individually foil shielded + overall 65% TC Braid
- Drain Wire
- PVC Insulation (power), FPE insulation (Data)
- Yellow CPE jacket
- Thin 80oC
- Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154 x 44) 17.5 Ω/ M', 57.4 Ω /km
- Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105 x 44) 28.0 Ω/ M', 91.9 Ω /km
- Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
- Nominal OD - 0.280", 7.11mm
Belden 7895A
- 300V Class 2 ODVA Cable III
- 20 and 18 AWG stranded TC
- 100% individually foil shielded + overall 65% TC Braid
- Drain Wire
- PVC Insulation (power), FPE insulation (Data)
- Lt. grey sunlight / oil resistant PVC jacket
- Mid 75oC
- Conductor (stranding) Diameter Nom. DCR - (2) 20 AWG TC (19 x 32) 10.9 Ω/ M', 35.8 Ω /km
- Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
- Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
- Nominal OD - 0.378", 9.60mm
Belden 7896A
- 600V Class 1 ODVA Cable V
- 16 and 18 AWG Stranded tinned copper
- 100% individually foil shielded + overall 65% TC Braid
- PVC / nylon insulation (power)
- F-R polypropylene insulation (data)
- Open wiring 600V 75oC
- Conductor (stranding) Diameter Nom. DCR - (2) 16 AWG TC (19 x 29) 4.9 Ω/ M', 16.1 Ω /km
- Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
- Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.7 Ω /km
- Nominal OD - 0.502", 12.75mm
Belden 7897A
- 600V Class 1 Thick
- 15 and 18 AWG Stranded tinned copper
- 100% individually foil shielded + overall 65% TC Braid
- Drain wire
- PVC / Nylon insulation (power); FEP Insulation (data)
- Lt. grey sunlight / oil resistant PVC jacket
- High velocity thick 600V 75oC
- Conductor (stranding) Diameter Nom. DCR - (2) 15 AWG TC (19 x 28) 3.6 Ω/ M', 11.8 Ω /km
- Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
- Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.7 Ω /km
- Nominal OD - 0.440", 11.18mm
Belden 7900A
- 600V Class 1 ODVA Cable IV
- 16 and 18 AWG Stranded tinned copper
- Unshielded
- PVC / Nylon insulation (power); FEP Insulation (data)
- Lt. grey sunlight / oil resistant PVC jacket
- High velocity thick 600V 75oC
- Conductor (stranding) Diameter Nom. DCR - (2) 16 AWG TC (19 x 29) 4.9 Ω/ M', 16.1 Ω /km
- Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
- Shielding materials Nom. DCR - Unshielded
- Nominal OD - 0.430", 10.92mm