The Belden 3084A Paired cable for DeviceBus® for ODVA DeviceNet™ 22 and 24 AWG stranded tinned copper conductors with sunlight / oil resistant PVC jacket.
Cable Construction
Number of Pairs: | 2 |
Number of Conductors: | 4 |
Conductor Material: | Tinned Copper (TC) |
AWG 22: | Stranding 19 x 34 |
AWG 24: | Stranding 19 x 36 |
Insulation Material: | Polyvinyl Chloride (PVC) |
Multi AWG Insulation Material: | AWG 22 - PVC |
AWG 24 FPE - Foam Polyethylene | |
Inner Shield Type: | Aluminium Foil Polyester Tape 100% Coverage |
Inner Shield Coverage: | 100% |
Inner Shield Drain Wire AWG: | 22 |
Inner Shield Drain Wire AWG: | 22 |
Inner Shield Drain Wire Stranding: | 19 x 34 |
Inner Shield Drain Wire Conductor Material: | Tinned Copper (TC) |
Outer Shield Type: | Braid |
Outer Shield Material: | Tinned Copper (TC) |
Outer Shield Coverage: | 65% |
Outer Jacket Material: | Polyvinyl Chloride (PVC) |
Overall Nominal Diameter: | 0.280" |
Mechanical Properties
Operating Temperature Range: | -20°C To +75°C |
UL Temperature Rating: | 75°C |
Bulk Cable Weight: | 41 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 65 lbs. |
Min. Bend Radius (Install): | 2.75" |
NEC/(UL) Specification: | CMG, CL2 |
CEC/C(UL) Specification: | CMG |
CSA Specification: | I/II A |
EU CE Mark (Y/N) | Yes |
EU RoHS Compliant (Y/N) | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 04/01/2005 |
Other Specification: | ODVA Class 2 Thin |
UL Flame Test: | UL1685 FT4 Loading |
CSA Flame Test: | FT4 |
Sunlight Resistance | Yes |
Oil Resistance: | Yes |
Plenum | No |
Electrical Properties
Nominal Characteristic Impedance 24 AWG Pair: | 120 Ohms |
Nominal Inductance 22 AWG Pair: | 0.221 μH/ft |
Nominal Inductance 24 AWG Pair: | 0.251 μH/ft |
Nominal Capacitance Conductor to Conductor @ 1KHz | 24 AWG pair 12.0 pF/ft |
Nominal Capacitance Conductor to Conductor: | 24 AWG Pair, 1kHz, 12.0 pF/ft |
Nominal Velocity of Propagation 24 AWG Pair: | 75% |
Maximum Delay 24 AWG Pair: | 1.36 ns/ft |
Maximum Conductor DC Resistance 22 AWG at 20°C: | 17.5 Ohms/1000 ft |
Maximum Conductor DC Resistance 24 AWG at 20°C: | 28.0 Ohms/1000 ft |
Nominal Outer Shield DC Resistance at 20°C: | 3.2 Ohms / 1000 ft |
Max Attenuation 24 AWG Pair Only: | 0.125 MHz : 0.29 dB/100 ft |
0.500 MHz : 0.50 dB/100 ft | |
1.000 MHz : 0.70 dB/100ft | |
Nominal Outer Shield DC Resistance at 20°C: | 3.2 Ohms/1000 ft |
Max. Attenuation 24 AWG Pair only 0.125 MHz: | 29 dB/100ft |
Max Attenuation 0.500 MHz: | 0.50 dB/100ft |
Max Attenuation 1.000 MHz: | 0.70 dB/100ft |
Max Operating UL Voltage 300 V RMS: | CL2, CMG |
Max Operating UL Voltage 300 V RMS: | C(UL) AWM |
Max Operating UL Voltage 600 V RMS: | UL AWM |
Max Recommended Current: | 1.7 Amps per conductor @ 25°C (24 AWG), 4 Amps per conductor @ 24 V per NEC CL2 (Power Pair) |
Flex Life: ±90 Degree Flex Test, 2" Diameter, 2 lbs. tension: 2000 Cycles minimum. Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark
Cable Ordering
Cable ID | Description | Cable Length (m) | Weight (kg) | Colour |
3084A 0021000 | 2 #22, 2 #24 SH PVC | 305 | 21.31 | Red |
3084A T5U1000 | 2 #22, 2 #24 SHLD PVC | 305 | 21.31 | Grey T5U |
3084A T5U2000 | 2 #22, 2 #24 SHLD PVC | 610 | 43.5 | Grey T5U* |
3084A T5U500 | 2 #22, 2 #24 SHLD PVC | 152 | 10 | Grey T5U |
*Final length may vary ±10% for reels or +/- 5% for unreel for lengths shown