The Belden 3082A data cable is a multi conductor, DeviceBus ® for ODVA DeviceNetTM.
Cable Construction
Cable Conductor 15AWG: | 1 Pair, 19 x 28 stranding |
Cable Conductor 18 AWG: | 1 Pair, 19 x 30 stranding |
Conductor Material: | Tinned Copper (TC) |
Insulation Material 15 AWG: | Polyvinyl Chloride (PVC) |
Insulation Material 18 AWG: | Foam Polyethylene (FPE) |
Inner Shield Material 15 AWG Pair: | Aluminium Foil Polyester Tape 100% Coverage |
Inner Shield Material 18 AWG Pair: | Aluminium Foil Polyester Tape 100% Coverage |
Outer Shield Material: | Tinned Copper (TC) Braid 85% coverage |
Outer Shield Drain Wire AWG: | 18 |
Outer Shield Drain Wire Stranding: | 19 x 30 |
Drain Wire Conductor: | Tinned Copper |
Outer Jacket Material: | Polyvinyl Chloride (PVC) |
Outer Jacket Thickness: | 1.524mm |
Overall Nominal Diameter: | 12.192mm |
1 (15 AWG) Pair Colour: | Red and Black |
2 (18 AWG) Pair Colour: | Blue & White |
Mechanical Properties
Operating Temperature Range: | -20°C to +75°C |
UL Temperature Rating: | 75°C |
Bulk Cable Weight: | 160.726 Kg/Km |
Max. Recommended Pulling Tension: | 845.158 N |
Min. Bend Radius/Minor Axis: | 121.920 mm |
NEC/(UL) Specification: | CMG, PLTC-ER |
CEC/C(UL) Specification: | CMG |
AWM Specification: | UL Style 20201 (600 V 75°C) |
EU Directive 2011/65/EU (ROHS II): | Yes |
EU CE Mark: | Yes |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 04/01/2005 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Other Specification: | ODVA Class 2 Thick |
UL Flame Test: | UL1685 FT4 Loading |
CSA Flame Test: | FT4 |
Sunlight Resistance: | Yes |
Oil Resistance: | Yes |
Plenum: | No |
Electrical Characteristics
Unaveraged Impedance 18 AWG Pair: | 120 Ohm |
Nominal Inductance 15 AWG Pair: | 0.570894 μH/m |
Nominal Capacitance Conductor to Conductor 18 AWG Pair: | 1 MHz / 39.372 pF/m |
Nominal Velocity of Propagation 18 AWG Pair: | 75% |
Maximum Delay 18 AWG Pair: | 4.46216 ns/m |
Nominal Conductor DC Resistance 15 AWG @ 20°C: | 11.8116 Ohm / km |
Nominal Conductor DC Resistance 18 AWG @ 20°C: | 22.6389 Ohm / km |
Nominal Outer Shield DC Resistance @ 20°C: | 5.9058 Ohm / km |
Maximum Attenuation 0.42653 (18 AWG Pair): | 0.125 MHz / 0.427 dB/100m |
Maximum Attenuation 0.82025 : | 0.5 MHz / 0.820 dB/100m |
Maximum Attenuation 1.3124 : | 1 MHz / 1.181 dB/100m |
Maximum Operating Voltage : | 300 V RMS (CL2,CMG) |
600 V RMS (UL AWM Style 20201) | |
300 V RMS (C(UL) AWM) | |
Maximum Recommended Current 15 AWG : | 8.0 Amps |
Maximum Recommended Current 18 AWG : | 5.0 Amps |
Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Associatio, Inc. Trademark. Jacket printed "1PR16" instead of
"1PR15" due to UL requirements for CMG Listing.
Cable Ordering Information
Cable ID | Cable Length m | Weight kg | Colour | Item Description |
3082A T5U2000 | 610 | 122 | Grey T5U | 2 #15, 2 #18 SHLD PVC |
3082A T5U3000 | 914 | 193 | Grey T5U | 2 #15, 2 #18 SHLD PVC |
3082A T5U500 | 152 | 31 | Grey T5U | 2 #15, 2 #18 SH PVC |