PLC / DCS Manufacturer |
System Name |
Belden CDT Part No. |
ABB / Bailey Controls
|
Infinet |
9880 - Network Trunk Cable 9463 - Blue hose (Standard) 9463LS - Steel Wire Armour 9463 |
Masterpiece 200 |
9880 - Network Trunk cable 9907 - Thin Network Trunk Cable |
Micro-DCI |
3105A - 1 pair, RS-485 |
Microlink |
9860 - Twinax, 16 AWG, 124 0hm 9860LS - Steel Wire Armour 9860 9860NH - low smoke, halogen free 9860 |
Modcell |
3105A - 1 pair, RS-485 |
Allen-Bradley / Rockwell Automation
|
ControlNetTM |
3092A - RG-6 PVC Quad shield 3092F - RG-6 PVC Quad shield, flex version, aluminium braid YR28890 - RG-6 PVC Flex version 3093A - RG-6 FEP* Quad shielded, Plenum 123092A - Aluminium armour (3092A) 133092A - steel armour (3092A) |
DeviceNetTM |
3082A - PVC (Thick) 3082F - High-flex (thick) 3082K - CL2 (Flat) 3082KP - Auxiliary Power (flat) 3083A - CPE (thick) 3084A - PVC (thin) 3084F - high flex (thin) 3085A - CPE (thin) 7895A - CL2 PVC (cable III Mid) 7896A - CL1 PVC (type V Trunk Cable) 7897A - CL1 PVC (thick) 7900A - CL1 Unshielded (drop cable IV) |
DH |
9463 - Blue Hose (Standard) 9463LS - Steel wire armour 9463 9463NH - Low smoke, halogen-free 9463 9463F - flexible version 129463 - aluminium armour (9463) 139463 - steel armour (9463) 189463 - cast aluminium (9463) YR28 826 - dual version (9463) 9463DB - Direct Burial (9463) YR29565 - various colour jackets (9463) 3072F - 600V TC rated (9463) YR28764 - super thick (PLTC) 89463 - FEP* 200°C, Plenum |
DH-485 |
3074F - 600V tray cable 3106A - 1.5 pair, RS 485 (PLTC) 9842 - 2 pair, RS-485, NH, LS 9842LS - Steel wire armour 9842 9842NH - low smoke, halogen free 9842 TM39500 - flexible version (3106A) |
Longline Communications |
8723 - Interface cable 88723 - Plenum version |
Cutler Hammer / Westinghouse
|
IMPACC System |
YR29090 - Proprietary Trunk Cable |
I/Q System |
9463 - Blue Hose (standard) 9463LS - steel wire armour 9463 9463NH - low smoke, halogen free 9463 |
Emerson Process Management (Fisher / Rosemount Controls)
|
Fieldbus IEC 61158-2(Type SP50 ISA/IEC) |
3076F - Type A, H1 1900m (31.25K) 3076ELS - steel wire armour 3076F 3076ENH - low smoke, halogen-free 3076F 3077F - Type B, H1 1200m (31.25K) 3077ELS - Steel wire armour 3077F 3077ENH - Low smoke, halogen free, 3077F 3078F - high speed (1.0 + 2.5 mbits / s) HSE - Copper and Fibre |
Hart |
3105A - 1 pair, RS-485 3106A - 1.5 pair, RS-485 3107A - 2 pair, RS-485 |
Provox Plus |
3094A - RG-11 Quad shield PVC 3131A - RG-6 Quad shield PVC |
GE Fanuc
|
Genius I/O System |
YR29841 - PLTC Version 9182 - communication bus 89182 - Plenum version |
Honeywell
|
Access 4000 system |
9248 - RG-6 PVC |
Fieldbus IEC 61158-2 (Type SP50 ISA / IEC) |
3076F - Type A, H1 1900m (31.25K) 3076ELS - steel wire armour 3076F 3076ENH - low smoke, halogen-free 3076F 3077F - Type B, H1 1200m (31.25K) 3077ELS - Steel wire armour 3077F |
IPC 620 System I/O |
9271 - Twinax, 25 AWG, 124 Ohm |
IPC 620 System Serial Interface |
9729 - up to 4,000 ft 9182 - up to 10,000 ft 89182 - Plenum |
3000 UCN & LCN |
3131A - RG-6 Quad Shield PVC 9094A RG-11 Quad Shield PVC |
Honeywell Micro switch Division
|
Smart distributed system |
3086A - Mini 3087A - Micro |
Invensys / Foxboro
|
Fieldbus IEC 61158-2 (Type SP50 ISA / IEC) |
3076F - Type A, H1 1900m (31.25K) 3076ELS - steel wire armour 3076F 3076ENH - low smoke, halogen-free 3076F 3077F - Type B, H1 1200m (31.25K) 3077ELS - Steel wire armour 3077F |
I/A Series - Carrier Band |
8233 - Small Trunk 3095A - Plenum 9290 - Drop cable |
I/A Series - Fieldbus |
9207 - Twinax 9207NH - Low smoke, halogen-free 9207 89207 - 200°C, Plenum 3073F - 600V tray cable |
I/A Series - Node Bus |
9880 - Trunk Cable 89880 - Plenum version |
Limitorque
|
DCC 100 |
3105A - Actuator Bus Cable, 1 pair, RS-485 |
Matsushita
|
FP Series - C-Net |
9207 - Twinax, 20 AWG, Stranded 100 Ohm 9207NH - Low smoke Halogen Free 9207 9860 - Twinax, 16 AWG, Solid, 124 Ohm 9860LS - Steel wire armour 9860 9860NH - Low smoke, halogen free 9860 |
FP Series - MEWNET-F |
9207 - Twinax, 20 AWG, Stranded, 100 Ohm 9207NH - Low smoke, halogen free 9207 9860 - Twinax, 16 AWG, solid, 124 Ohm 9860LS - Steel wire armour 9860 9860NH - Low smoke, halogen-free 9860 |
FP - Series - MEWNET-H |
9248 - RG-6, 75 Ohm, 18 AWG |
FP - Series - MEWNET-TR |
9207 - Twinax, 20 AWG, stranded 100 Ohm 9207NH - low smoke, halogen-free 9207 9860 - Twinax, 16 AWG, solid, 124 Ohm 9860LS - Steel wire armour 9860 9860NH - Low smoke, halogen-free 9860 |
MEWNET-W |
9207 - Twinax, 20 AWG, stranded, 100 Ohm 9207NH - Low smoke, Halogen-free 9207 9806 - 4 pair, RS-232, RS-422 |
MEWNET-W2 |
9207 - Twinax, 20 AWG, stranded, 100 Ohm 9207NH - low smoke, halogen-free 9207 9860 - Twinax, 16 AWG, Solid, 124 Ohm 9860LS - steel wire armour 9860 9860NH - low smoke, halogen-free 9860 |
TRNET |
9207 - Twinax, 20 AWG, stranded, 100 Ohm 9207NH - low smoke, halogen free 9207 9860 - twinax, 16 AWG Solid, 124 Ohm 9860LS - steel wire armour 9860 9860NH - Low smoke, halogen-free 9860 |
Mitsubishi
|
DeviceNetTM |
3082A - PVC (Thick) 3082F - High-flex (thick) 3082K - CL2 (Flat) 3082KP - Auxiliary Power (flat) 3083A - CPE (thick) 3084A - PVC (thin) 3084F - high flex (thin) 3085A - CPE (thin) 7895A - CL2 PVC (cable III Mid) 7896A - CL1 PVC (type V Trunk Cable) 7897A - CL1 PVC (thick) 7900A - CL1 Unshielded (drop cable IV) |
CC-Link |
YR47205 - three conductor YR47198 - three conductor + power |
Melsecnet (II) 10 / 10 H |
1505A - precision RG-59 / U Coax 1505F - high flex 1505A 1506A - Plenum precision RG-59 / U, outdoor, Direct burial 8241 - Standard RG-59 / U Coax 8241F - High flex 8241F |
Profibus DP & FMS |
3079A - 300V Twinax 3079ALS - steel wire armour 3079A 3079ANH - low smoke, halogen free 3079A 3079E - stranded conductor 3079A |
Serial Communications |
8777 - control and instrumentation interconnect cable 8777LS - steel wire armour 8777 8777NH - low smoke halogen-free 8777 |
Modicon / Schneider AEG
|
Modbus |
8777 - Modem drop cable, 22 AWG, 3 pair 8777LS - Steel wire armour 8777 8777NH - Low smoke, halogen-free 8777 128777 - aluminium armour (8777) 138777 - steel armour (8777) 88777 - FEP* 200°C Plenum |
Modbus II |
3092A - RG-6 Quad shield PVC 3132A - RG-6 Quad shield 150°C Plenum 3092F - RG-6 Quad shield PVC, flexible version 123092A - aluminium armour (3092A) 133092A - steel armour (3092A) |
Modbus Plus |
YM29560 - 24 AWG, 1 Pair, RS-485 YC39000 - aluminium armour (YM29560) YC39222 - steel armour (3092A) YQ29258 - 24 AWG, 1 Pair, 150°C, Plenum |
Remote I/O |
3092A - RG-6 Quad shield PVC 3092F - RG-6 Quad shield PVC, flexible version 123092A - Aluminium armour (3092A) 133092A - steel armour (3092A) 123092F - aluminium armour, RG-6 Quad shield PVC 3132A - RG-6 Quad shield, 150°C, Plenum 3094A - RG-11 Quad shield PVC 123094A - Aluminium armour (3094A) 133094A - steel armour (3094A) 3095A - RG-11 Quad shield, 150°C, Plenum |
Omron
|
AS Interface |
3999E - Yellow Bus Cable |
CompoBus / D (DeviceNet) |
3082A - PVC (Thick) 3082F - High-flex (thick) 3082K - CL2 (Flat) 3082KP - Auxiliary Power (flat) 3083A - CPE (thick) 3084A - PVC (thin) 3084F - high flex (thin) 3085A - CPE (thin) 7895A - CL2 PVC (cable III Mid) 7896A - CL1 PVC (type V Trunk Cable) 7897A - CL1 PVC (thick) 7900A - CL1 Unshielded (drop cable IV) |
CompoBus / S |
9409 - 1 pair, 18 AWG, 300V PLTC Control 9318 - 1 pair, 18 AWG, 300V PLTC control, shielded 3073F - 600V Twinax tray cable 3076ENH - fieldbus, low smoke, halogen free 89740 - 1 pair, 18 AWG, 300V control |
Controller Link |
9207 - Twinax 9207NH - Low smoke, halogen free 9207 89207 - Twinax, 200°C, Plenum 9815 - 100Ohm Twinax, Direct Burial 3073F - 600V Twinax tray cable |
Sysbus-2 |
3073F - 600V tray cable twinax |
Sysmac Bus |
9841 - 24 AWG 1 pair, RS-485 9841LS - Steel wire armour 9841 9841NH - low smoke halogen-free 9841 3105A - 22 AWG 1 pair, RS-485 |
SYSMAC Link |
9231 - Coax |
Phoenix Contact
|
DevicenetTM |
3082A - PVC (Thick) 3082F - High-flex (thick) 3082K - CL2 (Flat) 3082KP - Auxiliary Power (flat) 3083A - CPE (thick) 3084A - PVC (thin) 3084F - high flex (thin) 3085A - CPE (thin) 7895A - CL2 PVC (cable III Mid) 7896A - CL1 PVC (type V Trunk Cable) 7897A - CL1 PVC (thick) 7900A - CL1 Unshielded (drop cable IV) |
Interbus®-S |
3119A - 18 / 3C, 24 / 3 Pair, Composite 3120A - 24 / 3 Pair |
Profibus DP FMS & PA |
3079A - 300V Twinax 3079ALS - steel wire armour 3079A 3079ANH - low smoke, halogen free 3079A 3079E - stranded conductor 3079A 3076F - 18 AWG, 2 conductors, Type A 3076ELS - Steel Wire Armour 3076F 3076ENH - Low smoke, halogen free 3076F |
Reliance / A-B
|
Auto Max Distributed Power |
MTB6002 - 2 Fibre breakout I 100255 - 2 Fibre loose tube PVC I 100266 - 2 Fibre loose tube CPE |
R-Net |
9259 - RG-59 PVC 89259 - RG-59, 200°C Plenum |
Rotork
|
Parkscan II E RS-485 |
3105A - 22 AWG, 1 Pair, RS-485 |
Siemens / Moore
|
FMC (Field Mountable Controller) |
3105A - 1 pair, RS-485 3106A - 1.5 pair, RS-485 3107A - 2 pair, RS-485 3108A - 3 pair RS-485 3109A - 4 pair, RS-485 |
Hiway |
9860 - Network trunk cable 9860LS - Steel wire armour 9860 9860NH - Low smoke, halogen-free 9860 |
Modulnet |
3094A - RG-11 Quad Shield PVC 3131A - RG-6 Quad Shield PVC |
Profibus DP & FMS (Purple) |
3079A - 300V Twinax 3079ALS - steel wire armour 3079A 3079ANH - low smoke, halogen free 3079A 3079E - stranded conductor 3079A |
Profibus PA |
3076F - 18 AWG, 2 conductors, Type A 3076ELS - Steel Wire Armour 3076F 3076ENH - Low smoke, halogen free 3076F |
SINEC Series H1 |
9907 - Thin Network Trunk Cable 9880 - Network trunk cable |
SINEC Series H2B |
3131A - RG-6 Quad shield 3094A - RG-11 Quad shield |
SINEC Series L1 |
31071A - 2 pair, RS-485 |
SINEC Series L2 |
3079A - 300V Twinax 3079ALS - Steel wire armour 3079A 3079ANH - low smoke, halogen free 3079A 3079E - Stranded conductor 3079A |
Thicknet Ethernet Trunk |
9880 - Network trunk cable 129880 - aluminium interlocked armour trunk 139880 - steel interlocked armour trunk 9880 - 10 Base 5 Network Trunk Cable 89880 - Plenum 9907 |
Thinnet Ethernet Trunk |
9907 - thin network trunk cable 10 base2 89907 - Plenum 9907 |
Smar
|
Fieldbus IEC 61158-2 (Type SP50 ISA / IEC) Profibus DP, FMS & PA |
3076F - Type A, H1 1900m (31.25K) 3076ELS - steel wire armour 3076F 3076ENH - low smoke, halogen-free 3076F 3077F - Type B, H1 1200m (31.25K) 3077ELS - Steel wire armour 3077F 3077ENH - Low smoke, halogen free, 3077F 3078F - high speed (1.0 + 2.5 mbits / s) HSE - Copper and Fibre 3079A - 300V Twinax 3079ALS - steel wire armour 3079A 3079ANH - low smoke, halogen free 3079A 3079E - stranded conductor 3079A |
RS-485 |
9841 - 1 pair 9841LS - steel wire armour 9841 9841NH - low smoke, halogen-free 9841 82841 - 1 pair, plenum 89841 - 1 pair, plenum, high temperature 9842 - 2 pair 9842LS - steel wire armour 9842 9842NH - Low smoke, halogen-free 9842 82842 - 2 pair, plenum 9843 - 3 pair 9843NH - low smoke, halogen free 9843 9844 - 4 pair 3105A - 1 pair (PLTC) 3106A - 1.5 pair (PLTC) 3107A - 2 pair (PLTC) 3108A - 3 pair (PLTC) 3109A - 4 pair (PLTC) |
Square D / Schneider AEG
|
FIP / Fieldbus |
3079A - 22 AWG, 1 pair shielded 3079ALS - steel wire armour 3079A 3079ANH - low smoke, halogen free 3079A 3079E - stranded conductor 3079A 123079A - Aluminium armour (3079A) |
Model 50, RS-422 cable |
8760 - 18 AWG, 1 pair shielded 128760 - aluminium armour (8760) |
Passport I / O - I / O Net |
3105A - 22 AWG, 1 Pair RS-485 123105A - Aluminium armour (3105A) 3106A - 22 AWG, 1.5 pair, RS 485 123106A - aluminium armour (3106A) |
Power Logic |
9841 - 24 AWG RS-485 9841LS - steel wire armour 9841 9841NH - Low smoke, halogen-free 9841 9842 - 24 AWG, 2 pair, RS-485 9842LS - Steel wire armour 9842 9842NH - Low smoke, halogen free 9842 |
Seriplex® |
3124A - CBL - 1822 - P20 3125A - CBL - 1622 - P16 3126A - CBL - 162212-P16 123124A - Aluminium armour - 3124A 123125A - Aluminium armour - 3125A 123126A - Aluminium armour - 3126A |
SY / Net Network Trunk Cable |
9463 - Blue Hose standard 9463F - Flexible version (9463) 129463 - Aluminium armour 139463 - Steel armour (9463) 189463 - Cast Aluminium (9463) YR28826 - dual version (9463) 9463DB - direct burial (9463) YR29565 - various colour jackets (9463) 3072F - 600V TC rated (9463) YR41194 - low smoke, halogen free YR28764 - super thick (PLTC) 89463 - FEP* 200°C, Plenum |
SY / Net TNIM Cable |
9272 - 20 AWG, 1 pair shielded 89272 - FEP* 200°C Plenum |
Yokogawa
|
Fieldbus IEC 61158-2Type SP50 ISA / IEC) |
3076F - Type A, H1 1900m (31.25K) 3076ELS - steel wire armour 3076F 3076ENH - low smoke, halogen-free 3076F 3077F - Type B, H1 1200m (31.25K) 3077ELS - Steel wire armour 3077F 3077ENH - Low smoke, halogen free, 3077F 3078F - high speed (1.0 + 2.5 mbits / s) HSE - Copper and Fibre |
Westinghouse
|
WDPF |
9292 - RG-11 PVC |