The Belden 3106A Multi Conductor EIA Industrial RS-485 PLTC/CM cable with 22AWG and UV resistance PVC sheath.
Cable Construction
Number of Conductors: | 1 |
Number of Pairs: | 1 |
Conductor AWG: | 22 |
Conductor Stranding: | 7 x 30 |
Conductor Material: | Tinned Copper (TC) |
Conductor Diameter: | 0.762mm |
Total Number of Conductors: | 3 |
Insulation Material: | Foam High Density Polyethylene (FHDPE) |
Outer Shield Material Layer 1: | 100% Beldfoil Aluminium Foil Polyester Tape |
Outer Shield Material Layer 2: | 65% Tinned Copper Braid |
Outer Shield Drain Wire AWG: | 22 |
Outer Shield Drain Wire Stranding: | 7 x 30 |
Drain Wire Conductor Material: | Tinned Copper |
Outer Jacket: | Polyvinyl Chloride (PVC) |
Cabling Colour Code: | 1: White / Orange Stripe |
2: Orange / White Stripe | |
3: Blue / White Stripe | |
Overall Nominal Diameter: | 7.620mm |
Pair Lay Length: | 76.2mm |
Mechanical Properties (Overall)
Operating Temperature Range: | -20°C To +60°C |
Non-UL Temperature Rating: | 60°C |
Bulk Cable Weight: | 71.434 Kg/Km |
Max. Recommended Pulling Tension: | 289.133 N |
Min. Bend Radius/Minor Axis: | 76.200 mm |
NEC/(UL) Specification: | CM, PLTC |
CEC/C(UL) Specification: | CM |
EU Directive 2011/65/EU (ROHS II): | Yes |
EU CE Mark: | Yes |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 10/01/2005 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
UL Flame Test: | UL1685 UL Loading |
CSA Flame Test: | FT1 |
Plenum | No |
Electrical Properties
Nominal Inductance: | 0.666043 μH/m |
Nom. Capacitance Conductor to Conductor: | 36.091 pF/m |
Nom. Capacitance Cond. to Other Conductor & Shield: | 68.5729 pF/m |
Nominal Velocity of Propagation: | 78% |
Nom. Conductor DC Resistance @ 20°C: | 48.2307 Ohm/km |
Nominal Outer Shield DC Resistance @ 20°C: | 9.1868 Ohm/km |
Nominal Attenuation at 1MHz Frequency: | 1.6405 dB/100m |
Max Operating Voltage UL: | 300 V RMS |
Max. Recommended Current @ 25°C: | 2.7 Amps / Conductor |
Input Impedance / Unfitted Impedance: | .5 - 10 MHZ, 120 ±12 Ohms |
Oil Resistance: Passes Oil Res II Per UL1277, Table 10.17. For CPE jacketed version order YR46721
Ordering Information
Order Code | Cable Length (m) | Shipping Weight (kg) | Colour | Description |
3106A 0101000 | 305 | 21.319 | Black | #22 FS PR,1#22PVCBRDPVC |
3106A 010500 | 152 | 11.34 | Black | #22 FS PR,1#22PVCBRDPVC |
3106A 0105000 | 1524 | 104.327 | Black | #22 FS PR,1#22PVCBRDPVC |
UL
- i) UL Test Reports are available on-line through the UL Client Document Access web portal.
- ii) UL Inspection Reports are also available through the UL Client Document Access web portal.
CSA
- i) CSA "Descriptive Report and Test Results" documents are available on the CSA Gateway Portal.
- ii) CSA Inspection Reports are maintained on the CSA issued 'flash drive' at each manufacturing location.
* other test data may be available if requested at time of order.