CW1128 External Cable
Solid plain annealed copper conductors, Cel-PE (cellular polyethylene) insulated, PJF-petroleum jelly filled, polyethylene sheath. Black.
Technical Information
Sheath Colour: | Black | |
Minimum Bending Radius: | 10 x Ø | |
Maximum Conductor Resistance at 20oC: | 91/ohm/km | |
Minimum Insulation Resistance at 20oC megaohms/km: | 1500 | |
Average Mutual Capacitance nanoFarads/km: | 56 (n/a to screened versions) | |
Diameter of Conductor - mm: | 0.5 | |
Size of Conductor - mm2: | 0.2 | |
Radial Thickness of Insulation - mm: | 0.2 | |
Nominal Diameter of Core - mm: | 0.9 | |
Operating Temperature: | Maximum: | 40oC* |
|
Minimum Bending: | 0oC |
*Max continuous temperature of standard jelly compound
Number of pairs | Conductor diameter | O/D (mm) | Weight (kg/km) |
2 | 0.5 | 6.8 | |
5 | 0.5 | 6.8 | |
10 | 0.5 | 8.3 | |
20 | 0.5 | 12.5 | |
50 | 0.5 | 15.5 | |
100 | 0.5 | 20.3 | |
CW1128/1198 Telephone Cable
Cable Application
For Interconnecting telephone equipment externally. CW1128/1198 external armoured cable may be used. It is UV and moisture resistant and can also be used for direct burial. Available from 5 pairs to 100 pairs. Also available with 0.9mm conductors. Solid plain annealed copper conductors 1/0.9, cellular polyethylene insulated, PJF - petroleum jelly filled, collective aluminium/mylar tape screen, polyethylene bedding, galvanized steel wire armour, PVC outer sheath. Black to BS3573 and CW1128/1198. Flame Propagation to BS4066 PTI and IEC 332PTI.
Number of pairs | Conductor diameter | O/Dmm | Weight kg/km |
5 | 0.63 | 16.7 | |
10 | 0.63 | 19.9 | |
20 | 0.63 | 24.8 | |
50 | 0.63 | 34.5 | |
Click to download our Catalogue PDF for CW 1128 Telephone Cable.