- Diameter of conductor: 24AWG
- Insulation: Pe, OD = <1mm
- Cable assembly: 4-pair
- Synthetic water-repellent tape
- Shield: Aluminium / polyester tape and continuity wire
- Sheath material: LSZH, PVC or PE
Electrical Characteristics
Conductor resistance at 20oC (Max) | 98.6 Ohm / KM |
Dielectric strength at 50Hz | 1 kV / 1 min |
Insulation resistance (min.) | 5000 MOhm / km |
Capacitance unbalance - pair to ground (max) | 800 pF / 500m |
Transfer impedance (Zt) at 10 MHz (max) | 100 mOhm / m |
Velocity (nom.) | 78% |
Characteristics impedance (Zc) from 1 to 100Mhz | 100 Ohm |
Environmental Characteristics
Transport and storage temperature : | 0 + 50oC |
Operating Temperature | -20 + 60oC |
Fire resistance | IEC 332-1 NFC32070 2.1 (Category C2) |
Mechanical Characteristics
No. of Pairs | Type of Jacket | Colour of Jacket | Conductor OD (mm) | Insulation OD (mm) | Cable OD (mm) nominal | Cable weight (kg / km) | Min laying Bending radius (mm) | Max. pullng tensions (N) |
4 pair | LSZH | Ivory | 0.51 | 0.98 | 5.90 | 38 | 50 | 80 |
4 pair | PVC | Grey | 0.51 | 0.98 | 5.90 | 37 | 50 | 80 |
4 pair | PE | Black | 0.51 | 0.98 | 5.90 | 40 | 50 | 80 |
Applications : IEEE 802.3; IEEE 802.5; FDDI; ATM; RNIS
Cable Standards : IEC 61156-5; EN 50288-1 a-6
Cabling system standards : IS 11801 ed. 2; EN 50173; EIA / TIA 568
Cabling system installation standards : EN 50174