Inverter, connection to frequency converters, 0.6/1 kV
Cable Construction
Conductor: | Flexible red copper or tinned acc. to IEC 60228, DIN VDE 0295 class 5 |
Cores Colour: | acc. to DIN VDE 0293 HD 308, (brown – grey – black) |
Stranding: | cores laying to concentric crowns to ensure roundness to the cable |
Screen: | aluminium stripe (100% covering), red copper braid of the same section as the phase conductor (for sections up to 16 mm2) or equal to half phase conductor, with a minimum of 16 mm2 (for section greater than 25 mm2) |
Outer sheath: | Special PUR compound black (RAL 9005) |
Cable Features
According to IEC 60502-1 and CEI 20-13, CEI-UNEL 35375
Technical Data
Nominal voltage: | 0.6/1 kV |
Test voltage: | Test voltage: 4 kV |
Temperature range: | |
Fixed installation: | -50°C up to + 90°C |
Flexible installation: | -40°C up to + 90°C |
Temperature at conductor: | |
in service: | + 90°C |
in short circuit: | + 250°C |
Min. bending radius: | 8 x d |
Resistance: | Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part 266-2-5, EN 50266-2-5, IEC 60332-3A, CEI 20-22/II |
Ordering Information
No. of cores x cross section n x mm2 |
Outer Ø ca. mm ±10% |
Current capacity at +30°C Amps |
Copper weight kg/km |
Cable weight approx. kg/km |
AWG no.*) |
3 x 2.5 + SH | 14.6 | 26 | – | 340 | 14 |
3 x 4 + SH | 15.8 | 34 | – | 400 | 12 |
3 x 6 + SH | 18.7 | 44 | – | 490 | 10 |
3 x 10 + SH | 21.7 | 61 | – | 720 | 8 |
3 x 16 + SH | 25.3 | 82 | – | 1040 | 6 |
3 x 25 + SH | 28.8 | 108 | – | 1410 | 4 |
3 x 35 + SH | 32.2 | 135 | – | 1870 | 2 |
3 x 50 +SH | 36 | 168 | – | 2400 | 1 |
3 x 70 + SH | 40.7 | 207 | – | 3360 | 2/0 |
3 x 95 + SH | 47.6 | 250 | – | 4350 | 3/0 |
3 x 120 + SH | 52.2 | 292 | – | 5540 | 4/0 |
3 x 150 + SH | 56.4 | 335 | – | 6880 | 250 MCM |
3 x 185 + SH | 64.8 | 382 | – | 8350 | 350 MCM |
3 x 240 + SH | 74.5 | 453 | – | 11540 | 450 MCM |
3 x 300 + SH | 85.5 | 523 | – | 13480 | 550 MCM |
Other dimensions and colours available on request.