We hold stocks of Contactors, Thermal overload relays, Manual Motor Starters, Soft starters, Inverters and Control devices such as lamps and pushbuttons. CSE have been distributing ASEA and Brown Boveri products since 1971 and have unrivalled experience in the range of products now offered in the UK.
Manual motor starter type MS116
Manual motor starters from ABB switch motors ON and OFF properly and protect them in case of overload and short circuit. The range covers motors with nominal current from 0.1A up to 100A.
If you are a Schiele customer, follow the link to an Excel conversion table.
Open design, enclosure IP 20 resistant to changeable climates. Quick fastening on mounting rails DIN EN 50 022, 35mm without auxiliary switch.
Click to buy the ABB Manual Motor Starters on-line.
MS 116 with thermal and electromagnetic trips, short circuit proof up to 50 kA
Rated Power | Setting Range | Type | Order No. | Short Circuit breaking Capacity | Rated Instantaneous |
400 V AC-3 kW |
A… A | Ics at 400 V AC kA |
short circuit setting A |
||
0.03 | 0.10 … 0.16 | MS116-0.16 | 1SAM250000R1001 | 50 | 1.25 … 1.87 |
0.06 | 0.16 … 0.25 | MS116-0.25 | 1SAM250000R1002 | 50 | 1.95 … 2.92 |
0.09 | 0.25 … 0.40 | MS116-0.4 | 1SAM250000R1003 | 50 | 3.12 … 4.68 |
0.12 | 0.40 … 0.63 | MS116-0.63 | 1SAM250000R1004 | 50 | 4.91 … 7.37 |
0.25 | 0.63 … 1.00 | MS116-1.0 | 1SAM250000R1005 | 50 | 9.20 … 13.8 |
0.55 | 1.00 … 1.60 | MS116-1.6 | 1SAM250000R1006 | 50 | 14.7 … 22.1 |
0.75 | 1.60 … 2.50 | MS116-2.5 | 1SAM250000R1007 | 50 | 23.0 … 34.5 |
1.5 | 2.50 … 4.00 | MS116-4 | 1SAM250000R1008 | 50 | 40.0 … 60.0 |
2.2 | 4.00 … 6.30 | MS116-6.3 | 1SAM250000R1009 | 50 | 63.0 … 94.5 |
4 | 6.30 … 10.00 | MS116-10 | 1SAM250000R1010 | 50 | 120 … 180 |
7.5 | 10.00 … 16.00 | MS116-16 | 1SAM250000R1011 | 16 | 192 … 288 |
5.5 | 8.00 … 12.0 | MS116-12 | 1SAM250000R1012 | 25 | 144 … 216 |
Technical Data
Standards | Conformity to standards | IEC / EN60947-1, IEC/EN60947-2, IEC/EN60947-4-1, UL 508, CSA C22.2 No. 14 | |||
Phase loss sensitivity | (acc. to IEC / EN 60947-4-1) | Yes | |||
Disconnecting feature | (acc. to IEC / EN 60947-2) | Yes | |||
General Data | Mounting position | Position 1-6 | |||
Degree of Protection | (acc. to IEC 60947-1) | IP20 | |||
Mechanical Durability | 100000 cycles | ||||
Electrical Durability | 100000 cycles | ||||
Utilisation Category | A | ||||
IEC | Rated Operational Voltage Ue | ||||
Main Circuit | Rated Operational voltage Ue | 690 V AC | |||
Rated Frequency | 50 / 60Hz | ||||
Trip Class | 10A | ||||
Isolation Data | Rated impulse withstand voltage Uimp | 6kV | |||
(acc. to IEC / EN 60947-1) | Rated insulation voltage Ui | 690 V | |||
Environmental Data | Ambient Air Temperature | ||||
Operation | Open – Compensated | -25 … +55oC | |||
Open | -25 … +70oC | ||||
Enclosed (IB132) | 0 … +40oC | ||||
Storage | -50 … +80oC | ||||
Vibration | (acc. to IEC / EN 60068-2-6) | 5 g / 3-150Hz | |||
Shock | (acc. to IEC/EN 60068-2-27) | 25g / 11 ms | |||
Connecting Capacity | Rigid | 1 or 2 x | 1 … 4 mm2 | ||
Flexible with ferrule | 1 or 2 x | 0.75 … 2.5mm2 | |||
Flexible without ferrule | 1 or 2 x | 0.75 … 2.5mm2 | |||
Stripping length | 9mm | ||||
Tightening torque | 0.8 … 1.2Nm | ||||
UL / CSA | |||||
Main circuit | Max operational voltage | 600 V AC | |||
Short circuit rating | 480 V AC | 0.16AIe 2.5A | 30 kA | ||
600 V AC | 5 kA | ||||
Connecting Capacity | Stranded | 1 or 2 x | AWG 16… 12 | ||
Flexible without ferrule | 1 or 2 x | AWG 16… 12 | |||
Stripping length | 9mm | ||||
Tightening torque | 10lb. in |
Accessories
Type | Order No. | |
Auxiliary switches, for front panel installation | ||
HKF1-11 | 1 NO + 1 NC | 1SAM201901R1001 |
Auxiliary switches, lateral attachment at right | ||
HK1-11 | 1 NO + 1 NC | 1SAM201902R1001 |
HK1-20 | 2 NO | 1SAM201902R1002 |
HK1-02 | 2 NC | 1SAM201902R1003 |
Signal contact for general “tripped” signal, lateral attachment at right | ||
SK1-11 | 1 NO + 1 NC | 1SAM201903R1001 |
SK1-20 | 2 NO | 1SAM201903R1002 |
SK1-02 | 2NC | 1SAM201903R1003 |
Undervoltage release, lateral attachment at left | ||
UA1-24 | 24V, 50Hz | 1SAM201904R1001 |
UA1-230 | 230V, 50Hz | 1SAM201904R1005 |
Undervoltage release with pre-mating auxiliary switch 2S, lateral attachment at left | ||
UA1-HK-24 | 24V, 50 Hz | 1SAM201905R1001 |
UA1-HK-230 | 230V, 50 Hz | 1SAM201905R1005 |
Locking Device | ||
SA1 | Lock adapter | GJF1101903R0001 |
SA3 | Locking device assy | GJF1101903R0001 |
Direct Adapter, for wiring to contactors | ||
BEA7 / 116 | Mini contactors B6 / B7 | 1SBN080906R1000 |
BEA16 / 116 | Contactors A9 / A12 / A16 | 1SBN081406R1000 |
BEA26 / 116 | Contactors A26 | 1SBN082406R1000 |
Phase Buses for cross wiring MS 116, 63A, 690V | ||
PS1-2-0 for 2 devices without auxiliary switches | 1SAM201906R1002 | |
PS1-3-0 for 3 devices without auxiliary switches | 1SAM201906R1003 | |
PS1-4-0 for 4 devices without auxiliary switches | 1SAM201906R1004 | |
PS1-5-0 for 5 devices without auxiliary switches | 1SAM201906R1005 | |
PS1-2-1 for 2 devices with 1 auxiliary switch | 1SAM201906R1012 | |
PS1-3-1 for 3 devices with 1 auxiliary switch | 1SAM201906R1013 | |
PS1 4-1 for 4 devices with 1 auxiliary switch | 1SAM201906R1014 | |
PS1-5-1 for 5 devices with 1 auxiliary switch | 1SAM201906R1015 | |
PS1-2-2 for 2 devices with 2 auxiliary switches | 1SAM201906R1022 | |
PS1-3-2 for 3 devices with 2 auxiliary switches | 1SAM201906R1023 | |
PS1-4-2 for 4 devices with 2 auxiliary switches | 1SAM201906R1024 | |
PS1-5-2 for 5 devices with 2 auxiliary switches | 1SAM201906R1025 | |
Power infeed blocks 63A, 690V, stranded 25mm2, flexible 16mm2 | ||
S1-M2 high | 1SAM201907R1002 | |
Cover for phase busses | ||
BS1-3 | 1SAM201908R1001 | |
Switch cubicle mounting kit IP 65, with axial extension triple lockable in Off position, locked in On position | ||
OHY2AJM | Twist knob red / yellow | 1SCA022384R7080 |
OXS5X180 | Axis 180mm | 1SCA022353R4620 |
MSMN Driver* | 1SAM101923R001 |
*For accommodating spindle and attachment to manual motor starter