Flexible Round Festoon Cables 0.6/1 (1.2) kV
Applications
Heavy duty rubber cable for control and power supplies. For festoon applications with mechanical tensile stress compared with dynamic stress.
Design
1. Conductor | Flexible, plain copper, “FSC”, better than IEC 60228 class 5 |
2. Insulation | RHEYCLEAN-HEPR better than IEC 60502-1 |
3. Inner sheath | Special synthetic rubber, better than EM6 according to prEN 50363 |
4. Outer sheath | Rubber compound EM7 according to prEN 50363 |
Colour: | Black |
Marking
RHEYFESTOON (N)3GRD5G
Number of cores – cross-section 0.6/1 kV – NEXANS – year
VDE Reg.No. 7891
Cores Identification
DIN VDE 0293 part 308/ HD 308 S2
4 cores: green/yellow – brown – black – grey
5 cores: green/yellow – blue – brown – black – grey
≥ 5 cores: black with white printed numbers – green/yellow (in the outer layer)
6 cores design: brown – black – grey – 3 green/yellow (in the interstices)
Standards
In line with DIN VDE 0250 part 812.
VDE Reg.No. 7891
Mechanical Properties
Tensile stress of the conductor | static | 15 N/mm2 |
dynamic | 30 N/mm2 | |
Bending radii | according to DIN VDE 298, | |
see construction characteristics page 3.1 E | ||
Tests | alternating/reversed bending test, roller bending test, | |
torsional resistance test | ||
Festoon speed | up to 240 m/min, higher speed upon request |
Chemical Properties
- Oil resistant.
- For indoor and outdoor applications. Moisture, UV and ozone resistance.
- Flame-retardant according to IEC 60 332 part 1.
Electrical and Thermal properties
Nominal voltage | Uo/U | 0.6/ 1 kV |
Maximum operating voltage in AC systems | Um | 1.2 kV |
Maximum operating voltage in DC systems | Vm | 1.8 kV |
Test voltage: | ||
– Power | 3.0 kV in AC | |
– Control | 2.0 kV in AC | |
Current rating (A) | according to DIN VDE 0298 part 4, | |
see electrical characteristics page 3.2 B | ||
Max. temperature at the conductor: | ||
– in service | + 90 °C | |
– under short-circuit conditions | + 250 °C | |
Max. surface temperature: | ||
– fixed installation | – 50 °C up to + 80 °C | |
– mobile operation | – 35 °C up to + 80 °C |
LSHF Halogen Free Flat Cables
Number of cores and nominal cross-section |
Outer diameter | Weight approx. |
Max. tensile load |
||
(mm2) | Min. (mm) | Max. (mm) | (kg/km) | (N) | |
POWER | 1 x 35* | 12 | 14 | 400 | 525 |
1 x 50* | 15 | 17 | 600 | 750 | |
1 x 70* | 16 | 18 | 800 | 1,050 | |
1 x 95* | 18 | 20 | 1,000 | 1,425 | |
1 x 120* | 20 | 22 | 1,300 | 1,800 | |
1 x 150 | 23 | 25 | 1,700 | 2,250 | |
1 x 185 | 25 | 27 | 2,000 | 2,775 | |
4 x 4* | 14 | 16 | 350 | 240 | |
4 x 6* | 16 | 18 | 500 | 360 | |
4 x 10* | 19 | 21 | 700 | 600 | |
4 x 16* | 22 | 25 | 1,100 | 960 | |
4 x 25* | 26 | 29 | 1,600 | 1,500 | |
4 x 35* | 29 | 32 | 2,100 | 2,100 | |
4 x 50* | 35 | 38 | 3,000 | 3,000 | |
3 x 35 + 3 x 16/3 | 27 | 30 | 1,750 | 1,575 | |
3 x 50 + 3 x 25/3 | 31 | 33 | 2,500 | 2,250 | |
3 x 70 + 3 x 35/3 | 36 | 39 | 3,600 | 3,150 | |
3 x 95 + 3 x 50/3 | 41 | 44 | 4,500 | 4,275 | |
5 x 4* | 16 | 19 | 500 | 300 | |
5 x 6* | 17 | 20 | 600 | 450 | |
5 x 10* | 20 | 23 | 900 | 750 | |
5 x 16* | 24 | 27 | 1,350 | 1,200 | |
5 x 25* | 29 | 33 | 2,000 | 1,900 | |
CONTROL | 12 x 1.5 | 15 | 17 | 450 | 270 |
18 x 1.5 | 17 | 19 | 650 | 405 | |
24 x 1.5* | 21 | 23 | 850 | 540 | |
30 x 1.5 | 22 | 24 | 950 | 675 | |
36 x 1.5 | 23 | 26 | 1,100 | 810 | |
12 x 2.5* | 17 | 20 | 600 | 450 | |
18 x 2.5* | 20 | 23 | 900 | 650 | |
24 x 2.5* | 23 | 26 | 1,150 | 900 | |
30 x 2.5* | 26 | 29 | 1,350 | 1,125 | |
36 x 2.5 | 28 | 31 | 1,600 | 1,350 | |
BUS | 6 x (2 x 0.5) C* | 20 | 22 | 780 | 180 |
6 x (2 x 1) C* | 24 | 27 | 810 | 180 | |
9 x (2 x 0.5) C* | 26 | 29 | 990 | 270 | |
9 x (2 x 1) C* | 33 | 36 | 1,080 | 270 | |
12 x 1 (C) | 16 | 18 | 590 | 180 |