Christmas Banner

Prysmian FP600 Cable

Prysmian FP600 ® is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and specifiers for many fire fighting and life safety applications. Its superior mechanical protection provided by an interlocking steel tape armour is, unlike standard single wire armour designs, maintained to a high level under fire conditions. This armour design ensures that FP600 meets the new generation fire test requirement currently given in BS7346-6:2005 "Components for smoke and heat control systems – Part 6 Specification for cable systems" which involves direct mechanical impact and water jet application under fire conditions.

FP600 achieves the maximum 120 minute rating under the BS7346-6 test conditions, which is required for fire fighting BSEN60332-1-2.

Conductor: Plain annealed copper stranded circular (10-35mm2)
Insulation: Primary Insulation:90°C cross – linked insulation
Core identification:
  • 2 core: Brown & blue
  • 3 core: Brown, black & grey
  • 4 core: Brown, grey, blue & black
Bedding: Extruded LSOH bedding compound
Armour/Protection: Single layer of interlocking steel tape
Sheath: Robust thermoplastic LSOH sheath. Colour – black.

Two Core FP 600

Nominal Cross Sectional Area mm2 Approximate overall diameter mm Approximate cable weight kg / KM Maximum conductor resistance at 20oC ohms / km Current rating DC or single phase AC Free Air Amps Current rating DC or single phase AC Clipped direct Amps Volt drop DC mV / A/ m Volt drop single phase AC mV / A/ m
10 24.3 900 1.83 90 85 4.7 4.7
16 25.5 1050 1.15 115 110 2.9 2.9
25 28.9 1375 0.727 152 146 1.85 1.9
35 32.7 1950 0.524 188 180 1.35 1.35
50* 33.4 2200 0.387 228 219 0.98 1.0
70* 36.6 2775 0.268 291 279 0.67 0.69
95* 38.3 3375 0.193 354 338 0.49 0.52
120* 41.9 4050 0.153 410 392 0.39 0.42

Three Core FP 600

Nominal Cross Sectional Area mm2 Approximate overall diameter Approximate cable weight kg / km Maximum conductor resistance at 20°C ohms / km Short circuit rating (1 sec) of conductor KA Current rating Three phase AC Clipped direct AMPS Current rating Three phase AC Free Air Amps Volt drop Three Phase AC mV/A/m
10 24.9 1125 1.83 1.4 73 78 4.0
16 27.4 1350 1.15 2.2 94 99 2.5
25 32.4 1975 0.727 3.6 124 131 1.65
35 35.2 2375 0.524 5.0 154 162 1.15
50* 36.2 2775 0.387 7.1 187 187 0.87
70* 39.8 3550 0.268 10.0 238 251 0.60
95* 43.7 4500 0.193 13.6 289 304 0.45
120* 46.0 5400 0.153 17.2 335 353 0.37

Four Core FP 600

Nominal Cross Sectional Area mm2 Approximate overall diameter Approximate cable weight kg / km Maximum conductor resistance at 20°C ohms / km Short circuit rating (1 sec) of conductor KA Current rating Three phase AC Clipped direct AMPS Current rating Three phase AC Free Air Amps Volt drop Three Phase AC mV/A/m
10 26.5 1250 1.83 1.4 73 78 4.0
16 29.3 1500 1.15 2.2 94 99 2.5
25 33.6 2325 0.727 3.6 124 131 1.65
35 37.7 2825 0.524 5.0 154 162 1.15
50* 39.1 3400 0.387 7.1 187 197 0.87
70* 43.8 4450 0.268 10.0 238 251 0.60
95* 47.6 5625 0.193 13.6 289 304 0.45
120* 51.8 6900 0.153 17.2 335 353 0.37

*Shaped conductor